Before the Holiday Shutdown: A Checklist for Lines Left Unattended

Stainless steel pressure gauges

A-Best Industrial Inc. Fittings, Valves, and Tubing |

A four-day weekend is a long time for a slow leak to go unnoticed. A fitting that seeps a little on Wednesday can empty a gas cylinder by Monday, and a hose that's been rubbing for months picks the quiet days to let go. A short walkdown before everyone leaves heads off most holiday callouts.

1. Walk the lines and listen

With the plant still running, walk your instrument, gas and hydraulic lines. A hiss, the smell of gas, an oily drip under a fitting or frost on a gas line are all signs to deal with before you leave, not after.

2. Bubble test the usual suspects

Focus on anything that was worked on recently, anything that shakes, and threaded connections. With lines at normal pressure, apply Gator Leak Detector all the way around each joint, including the pipe-thread side of male connectors, and watch for bubbles or foam. If something leaks, isolate and depressurize before you put a wrench on it. Never tighten a fitting under pressure.

Gator Leak Detector 8 oz bottle

3. Look hard at hoses

Check for cracked or blistered covers, exposed braid, kinks, crushed spots, hoses rubbing on steel and fittings that are weeping. Any one of those is a reason to replace the hose now. Our post on signs it's time to replace a hose assembly has the full list. We build most hose assemblies while you wait.

4. Isolate what won't be used

  • Close cylinder valves on gas lines that won't run over the break, and bleed the regulators.
  • Close isolation valves to equipment that's shut down, so a failure downstream can't drain the whole system.
  • Cap or plug any open lines from unfinished work. A rag isn't a cap. Use DK-Lok caps and plugs and see our post on capping and plugging a line.

5. Note your gauge readings

Write down or photograph the pressure on key gauges before you leave. When you come back, a drop tells you there's a leak somewhere, even if nobody heard it. Replace any gauge with a cracked lens, a bent pointer or a needle that won't return to zero.

6. Check relief valves and vents

Make sure relief valve outlets and vent lines aren't blocked, capped or pointed where they could hurt someone. A relief valve that's been weeping is telling you something. See why a relief valve leaks.

7. Support anything that shakes

Equipment that keeps running over the holiday, like compressors and pumps, keeps shaking the tubing attached to it. Make sure those lines are clamped close to the fittings so vibration isn't working them loose while nobody's watching. Our tube clamps cover single lines, bundles and strut racks.

8. Stock the spares

If something does fail, the person on call needs parts. Keep a small kit of the tube fittings, ferrules, caps and plugs, and tubing your systems use, plus a tube cutter and deburring tool from our tools page. DK-Lok tube fittings are 100% interchangeable and intermixable with Swagelok and Parker A-Lok for like size and material, per DK-Lok's ASTM F1387 test report (14 intermixed combinations, witnessed by TÜV Rheinland, "No failure observed") and the Parker A-Lok interchangeability letter, so one spares kit can cover mixed systems.

If something fails anyway

A-Best Industrial Inc. Fittings, Valves, and Tubing offers after-hours emergency service. Call (310) 892-3503 or (310) 987-0192. During regular hours, Monday through Friday, 8:00 AM to 5:00 PM Pacific, call 310-833-3353 or email sales@abesttube.com. Have a safe holiday.