Working on CNG Fueling Equipment? Hose, Valve and Fitting Tips

Working on CNG Fueling Equipment? Hose, Valve and Fitting Tips

A-Best Industrial Inc. Fittings, Valves, and Tubing |

Compressed natural gas fueling equipment looks a lot like any other gas system until you remember what's inside it: a flammable gas stored and dispensed at pressures well above what most plant air and utility lines ever see. On a CNG station, a small leak isn't just lost product. It's a fire risk sitting next to buses, trucks and people.

I've worked around a lot of high-pressure gas systems. The techs who stay safe on CNG aren't the fastest. They're the ones who check the same things every time. Here's my list.

CNG fueling station dispensers where hoses, valves and tube fittings see high-pressure natural gas

Respect the Pressure Before You Touch Anything

Follow your site's lockout/tagout and gas-handling procedures every time. Isolate the section you're working on, vent it to a safe location per your procedure, and verify zero before you break a single connection. Never loosen a fitting or hose end to "see if it's bled down." Keep ignition sources away, and if your site requires a gas detector, have it on and working.

Inspect Dispenser Hoses Like Your Life Depends on It

Fueling hoses get dragged across concrete, run over, kinked and left in the sun. Look the whole length over, not just the ends. Pull it from service if you see cuts or abrasion through the cover, bulges, kinks, crushed spots, or corrosion or movement at the crimped fittings. Check the breakaway and the nozzle for damage, too.

When a hose comes out, replace it with an assembly built for CNG service, not a general-purpose hose that happens to fit the threads. A-Best Industrial Inc. Fittings, Valves, and Tubing builds CNG hose assemblies at our CNG certified facility, so what goes back on the dispenser is made for the job. See our hose assemblies page for details.

CNG hose assemblies fueling a bus, a trash truck and a vehicle

Use Valves Rated for CNG Service

Every isolation valve on a CNG skid, panel or dispenser should be rated for the gas and the working pressure of that part of the system. Don't swap in a general utility ball valve because it's what's on the truck. DK-Lok offers ball valves specifically for CNG/NGV service. Check the valve's rating against your system before it goes in, and ask us if you're unsure. You'll find more options in our ball and plug valves collection.

DK-Lok VC86 series ball valve for CNG and NGV service

Make Up Tube Fittings Right the First Time

Most of the tubing on CNG equipment is stainless, and the tube fittings are only as good as the prep. Cut square with a tube cutter made for stainless, and lock a GRIP-IT TOOL on the tube so it doesn't spin in your hand while you cut. Deburr inside and out with a deburring tool. Bottom the tube in the fitting, follow the manufacturer's turns from finger-tight, and check the make-up with a gap inspection gauge. All of these are on our tools page.

Many stations already have Swagelok fittings in place. DK-Lok tested intermixing to ASTM F1387-99(2005), witnessed by TÜV Rheinland, using 14 combinations of DK-Lok and Swagelok nuts, front ferrules, back ferrules and bodies in 1/4" through 1" OD. Tests included pneumatic and hydrostatic proof, impulse, vibration, thermal cycling and hydrostatic burst, where ruptures were in the tube, not the fittings. The stated result was "No failure observed," and DK-Lok backs the intermix in writing for properly assembled, same-size, same-material Swagelok components. Read the ASTM F1387 test report.

DK-Lok male adapter stainless steel tube fittings

Leak Check Before It Goes Back in Service

Once the system is repressurized per your procedure, check every connection you touched. Apply Gator Leak Detector all the way around each joint and watch for bubbles or foam. If something leaks, isolate and vent before you put a wrench on it. Never tighten a fitting under pressure.

Gator Leak Detector bottle for checking CNG tube fitting and hose connections

If your crew is new to high-pressure gas work, our free Safety training course for new and existing customers is a good place to start.

We're Here to Help

Need a CNG hose assembly, CNG-rated valves or tube fittings for a station repair? Call A-Best Industrial Inc. Fittings, Valves, and Tubing at 310-833-3353 or email sales@abesttube.com. We're open Monday–Friday, 8:00 AM–5:00 PM Pacific, with after-hours emergency service.